MGE UPS Systems FlexPDU 6 UNI Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Unités d'alimentation électrique MGE UPS Systems FlexPDU 6 UNI. UPS & Power Quality Products Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer

Résumé du contenu

Page 1 - Quality Products

Pulsar Series Product CatalogueUPS & Power Quality ProductsSouth Asia

Page 2 - Contents

10The highest level of protection for business computersUPS control panel• Log• Alarms sent by SMS or e-mail• When there is a long power cut, the syst

Page 3 - Worldwide

11TECHNICAL SPECIFICATION 600 USBS 750 USBS 1000 USBS 1500 USBSRating (VA / Watt) 600/360 750/450 1000/600 1500/900 Technology Standby Standby St

Page 4 - Sustainable by Design

12Power protection for workstations and small serversEllipse MAXLine Interactive technology: Ellipse MAX provides effective • protection, even in dist

Page 5 - Power Quality Business

13TECHNICAL SPECIFICATION 600 USBS 850 USBS 1100 USBS 1500 USBS Rating (VA / Watt) 600 VA / 360 W 850 VA / 550 W 1100 VA / 660 W 1500 VA / 900 W

Page 6

14High density protection for network devicesEvolutionLine-interactive HF technology: • the best price/performance ratioNo additional cost:• RT mod

Page 7

15 TECHNICAL SPECIFICATION 1550 2000Rating (VA / Watt) 1550 VA / 1100 W 2000 VA / 1600 WFormat Tower RT2U (tower/rack 2U)CharacteristicTechnology Line

Page 8 - Nova AVR

16High density protection for network devicesEvolution SLine-interactive HF technology: • the best price/performance ratioNo additional cost:• all

Page 9 - *2 IEC cables supplied

17 TECHNICAL SPECIFICATION 1250 2500 3000Rating (VA / Watt) 1250 VA / 1150 W 2500 VA / 2250 W 3000 VA / 2700 WFormat RT2U (tower / rack 2U) RT2U (towe

Page 10 - Ellipse ASR

18Series 9 protection for all critical applicationsEXConfiguration. Double conversion on-line UPS with automatic • by-pass and power factor correction

Page 11

191: Maximum rating with EXB battery units: EX 1000 = 800 W, EX 1500 =1200 W. EX 3000 = 2400 W 2: Lower limits for <20%, <33%, <66%, >=66%

Page 12 - Ellipse MAX

2Uninterruptible Power SuppliesCorporate Overview ...3Sustainability ...

Page 13

20Superior de-centralised power protection for medium to high MXTwo front access hot-swappable sub-modules (power and • battery) for maintenance witho

Page 14 - Evolution

21 TECHNICAL SPECIFICATION 5 kVA 15 kVA 20 kVARating (kVA) / (kW) 5 kVA / 4,5 kW 15 kVA / 13, 5 kW 20 kVA / 18 kW Technology VFI-SS-113, online dou

Page 15

22Perfect for rack servers enclosures and industrial environmentEX RTSystem to support up to 8 modules (1 hour runtime + 1 transformer module). Ideal

Page 16 - Evolution S

23 TECHNICAL SPECIFICATION 7 kVA 11 kVATechnology online double conversion with PFC (Power Factor Correction) system (1)Active power kVA / kW 7 / 4.9

Page 17

24Source Transfer SwitchSTS 16At present, only top-of-the-range servers are equipped with a dual electrical power supply. In their original form the

Page 18

25 TECHNICAL SPECIFICATION STS 16 Nominal current 16 A Compatibility with all uninterruptible power supplies which use on-line double conversion tec

Page 19

26Power Distribution for UPSFlex PDU / HotSwap MBP / Comet PDUFlexPDU - Having the right connectors just where you need themHotSwap MBP- High availabi

Page 20

27 TECHNICAL SPECIFICATION FlexPDU HotSwap MBP Comet PDU Current rating 16 A 16 A 52 A Voltage rating 220-230-240-250 V 220-230-240-250 V 220-2

Page 21

28Improve equipment reliability and guarantee data integrityNetwork Management ProxyNetwork Management CardSupervision using a web browserSupervision

Page 22

29Individual outlet socket controlRemote on/off controlSaving energy functionTo ensure the integrity of the system and the data, a computeroperating s

Page 23 - 2: single phase input value

3Founded in 1911, Eaton® Corporation is a diversified industrial manufacturer and a global leader in various industrial markets, including: Electrica

Page 24 - Source Transfer Switch

30Connection to IP networksNetwork Management Card (Web/SNMP)66 102 NMC “Minislot” for Eaton Evolution and Eaton Evolution S, Eaton EX, Eaton MX, Eato

Page 25

UPS Quick Selection GuideTechnology VA Range Model Protection Against Output Cabinet ConfigurationOutput SocketExtended Battery CapabilityStandby/Of

Page 26 - Power Distribution for UPS

For more product information please contactEaton's Electrical SectorSouth AsiaEaton Power Quality Pvt. Ltd.Unit No. 1, Second Floor, TDI Centre,

Page 27

4Sustainability has always been at the heart of Eaton's business – this means meeting the current needs of our society while enabling future gene

Page 28 - Power Management Solutions

5Eaton Power Quality Division, a part of the Electrical Sector, has more than 45 years of experience in designing and producing innovative power quali

Page 29 - Additional functions

6Eaton offers the largest selection of power management and protection solutions available in the industry. From the desktop to the data centre, from

Page 30 - Network Shutdown Module

7Single-Phase Products And SolutionsEaton's power management solutions are based on protecting the nine most common power problems present in any

Page 31 - UPS Quick Selection Guide

8Cost-effective solution for protection personal and professional PCNova AVRPersonal Solution-Pac software can be interfaced with NOVA AVR for advance

Page 32 - Sales and Service Operations

9 TECHNICAL SPECIFICATION 625 AVR 1250 AVR Rating (VA / Watt) 625 VA / 360 W 1250 VA / 660 W CharacteristicInput voltage 165 V to 280 V 160 V to 2